Journal of the Formosan Medical Association
Volume 108, Issue 12 , Pages 943-949, December 2009

Frontalis Suspension Using Expanded Polytetrafluoroethylene: Results of Different Surgical Designs

  • Yi-Hsuan Wei
  • ,
  • Shu-Lang Liao

      Affiliations

    • Corresponding Author InformationCorrespondence to: Dr Shu-Lang Liao, Department of Ophthalmology, National Taiwan University Hospital, 7 Chung Shan South Road, Taipei 100, Taiwan

Department of Ophthalmology, National Taiwan University Hospital, Taipei, Taiwan

Received 6 October 2008; received in revised form 13 May 2009; accepted 3 June 2009.

Article Outline

Background/Purpose

Several surgical designs and materials have been proposed for frontalis suspension for treating congenital ptosis and ptosis with poor levator muscle function. This study evaluated the surgical results of frontalis suspension using expanded polytetrafluoroethylene (ePTFE) with two different surgical designs (open-type and closed-type).

Methods

We reviewed the medical records of 96 patients (68 children and 28 adults) who underwent frontalis suspension surgery using ePTFE. Postoperative eyelid position, ptosis recurrence, and complications were recorded.

Results

Twenty-eight out of 68 children and all 28 adults underwent closed-type frontalis suspension surgery, and 40 children underwent open-type surgery. The recurrence rate was 20% (8 of 40 eyelids) for children with closed-type surgery, and 2% (1 of 50 eyelids) for those with open-type surgery. There was a statistically significant difference in the recurrence rate between the two surgical methods in children (p = 0.011). The recurrence rate was 5% (2 of 40 eyelids) in adults who underwent the closed-type method. The recurrence rate after closed-type surgery was significantly different between the child and adult groups (p = 0.04).

Conclusion

Open-type frontalis suspension surgery using ePTFE is preferable to closed-type surgery for children with upper eyelid ptosis. Closed-type surgery provides more favorable results in adults than in children.

Key Words:  blepharoptosis , frontalis suspension , polytetrafluoroethylene

No full text is available. To read the body of this article, please view the PDF online.

 

Back to Article Outline

References 

  1. Ben Simon GJ , Macedo AA , Schwarcz RM , et al.   Frontalis suspension for upper eyelid ptosis: evaluation of different surgical designs and suture material . Am J Ophthalmol . 2005;140:877–885
  2. Leibovitch I , Leibovitch L , Dray JP . Long-term results of frontalis suspension using autogenous fascia lata for congenital ptosis in children under 3 years of age . Am J Ophthalmol . 2003;136:866–871
  3. Carter SR , Meecham WJ , Seiff SR . Silicone frontalis slings for the correction of blepharoptosis: indications and efficacy . Ophthalmology . 1996;103:623–630
  4. Wasserman BN , Sprunger DT , Helveston EM . Comparison of materials used in frontalis suspension . Arch Ophthalmol . 2001;119:687–691
  5. Mehta P , Patel P , Olver JM . Functional results and complications of Mersilene mesh use for frontalis suspension ptosis surgery . Br J Ophthalmol . 2004;88:361–364
  6. Ibrahim HA . Use of the levator muscle as a frontalis sling . Ophthal Plast Reconstr Surg . 2007;23:376–380
  7. Yagci A , Egrilmez S . Comparison of cosmetic results in frontalis sling operations: the eyelid crease incision versus the supralash stab incision . J Pediatr Ophthalmol Strabismus . 2003;40:213–216
  8. Bagheri A , Aletaha M , Saloor H , et al.   A randomized clinical trial of two methods of fascia lata suspension in congenital ptosis . Ophthal Plast Reconstr Surg . 2007;23:217–221
  9. Steinkogler FJ , Kuchar A , Huber E , et al.   Gore-Tex soft-tissue patch frontalis suspension technique in congenital ptosis and in blepharophimosis-ptosis syndrome . Plast Reconstr Surg . 1993;92:1057–1060
  10. Kersten RC , Bernardini FP , Khouri L , et al.   Unilateral frontalis sling for the surgical correction of unilateral poor-function ptosis . Ophthal Plast Reconstr Surg . 2005;21:412–417
  11. Mencia-Gutierrez E , Clariana-Martin A , Gutierrez-Diaz E , et al.   Results and complications of expanded polytetrafluoroethylene in frontalis suspension ptosis surgery. Study of 59 cases . Arch Soc Esp Oftalmol . 2005;80:443–448 [In Spanish]
  12. Wang HZ , Chang CH , Su MY , et al.   Use of Gore-Tex sling in brow suspension procedure . Gaoxiong Yi Xue Ke Xue Za Zhi . 1994;10:131–137
  13. Kuchar A , Ofluoglu A , Novak P , et al.   Frontalis suspension with “expanded polytetrafluoroethylene (ePTFE) strips” in congenital ptosis . Klin Monatsbl Augenheilkd . 1997;211:37–40 [In German]
  14. El-Toukhy E , Salaem M , El-Shewy T , et al.   Mersilene mesh sling as an alternative to autogenous fascia lata in the management of ptosis . Eye . 2001;15:178–182
  15. Junceda-Moreno J , Suarez-Suarez E , Dos-Santos-Bernardo V . Treatment of palpebral ptosis with frontal suspension: a comparative study of different materials . Arch Soc Esp Oftalmol . 2005;80:457–461 [In Spanish]
  16. Wheatcroft SM , Vardy SJ , Tyers AG . Complications of fascia lata harvesting for ptosis surgery . Br J Ophthalmol . 1997;81:581–583
  17. Bajaj MS , Sastry SS , Ghose S , et al.   Evaluation of polytetrafluoroethylene suture for frontalis suspension as compared with polybutylate-coated braided polyester . Clin Experiment Ophthalmol . 2004;32:415–419

PII: S0929-6646(10)60007-1

doi:10.1016/S0929-6646(10)60007-1

Journal of the Formosan Medical Association
Volume 108, Issue 12 , Pages 943-949, December 2009